The Northstar Active Care Rehab system contains the essential tools to determine treatment plans by objectively documenting range of motion and muscle strength physical abilities. Users gain a competitive edge by choosing our integrated wireless devices for automated data collection. This integrated system allows users to focus more time on patient care and less time on transcription and paperwork. Plus, each instrument module comes with demonstration videos based on established best practices and published protocols to ensure proper testing technique.

 

ns inclinometry lumbar laptop

Validate Med-Legal Cases

  • Helps users to determine proper treatment and validate their treatment plans with objective documentation throughout the rehabilitation process
  • Compliant with insurance requirements
  • Provides the necessary data needed to document medical necessity and meet ICD-10 requirements
  • Northstar’s instrument testing modules deliver fast, accurate testing results to assess deficits for physical strength and range of motion

Included in this System:

Allows users to objectively evaluate and document range of motion for spine and large extremities.
Documents strength of a muscle or group of muscles for a variety of tasks that require a certain level of strength.
Tests and documents max grip strength at multiple intervals, 5-position grip test, rapid exchange grip, and sustained grip.

 

 ns grip testing laptop

Northstar Software

  • Accurate testing results for physical deficits and consistency of effort over time to prove a patient’s med-legal claims
  • Automatic calculations of grip strength eliminate the possibility of human error, resulting in more objective data to back up any legal claims
  • Automatically calculates results for max and average range of motion
  • Automated AMA test validity for spinal range of motion and difference compared to standard published norms
  • Shows force curves in real-time for reliability of effort and/or neurological test results
  • Quick and easy comprehensive test reports can be produced in just seconds
  • Easy-to-read bar graphs clearly display a patient’s level of bilateral deficits to validate their case for personal injury
Product Info:

Part Number: 9RF403, 9RF404 (primary and secondary set)
Units of Measure: Degree (angle)
Weight: 0.20 lb (0.09 kg)
Length: 2.85 in (7.24cm)
Width: 1.05 in (2.67 cm)
Depth: 2.59 in (6.58cm)
Battery Type: Rechargeable Lithium Polymer
Battery Life: Approx. 10-14 hours of continual use

Part Number: 9RF403, 9RF404 (primary and secondary set)
Weight: 0.20 lb (0.09 kg)
Length: 2.85 in (7.24cm)
Width: 1.05 in (2.67 cm)
Depth: 2.59 in (6.58cm)
Battery Type: Rechargeable Lithium Polymer
Battery Life: Approximately 10-14 hours of continual use

Part Number: 9RF405
Units of Measure: lb, kg, N
Weight: 0.45 lb (0.02 kg)
Length: 4.02 in (10.2 cm)
Width: 2.40 in (6.1 cm)
Height: 2.11 in (5.3 cm)
Battery Type: Rechargeable Lithium Polymer
Battery Life: Approximately 10-14 hours of continual use

Part Number: 9RF406
Load Cell Capacity: 200 lb (0.42 kg)
Units of Measure: lb, kg, N
Weight: 0.92 lb (0.42 kg)
Length: 8.15 in (20.70 cm)
Width: 1.62 in (4.11 cm)
Height: 4.01 in (10.19 cm)
Battery Type: Rechargeable Lithium Polymer
Battery Life: Approximately 10-14 hours of continual use

Alignment Rails (8MH068) – Magnetically attach to the Inclinometers for easy visual confirmation of alignment
VELCRO® Straps (45, 46, 47) – Can be used for dynamic range of motion inclinometry testing. Comes in a set containing Small, Medium, and Large straps

Flat Pad (8AC008) – The flat pad can be used for exerting force against flat items.
Curved Pad (8AC009) – The curved pad can be used for exerting force against items that are rounded.
Muscle Tester Cradle (8AC009) – The muscle tester cradle provides a stable platform to rest the muscle tester.

Get Up and Running with Northstar

Up and Running: Intake
Up and Running: Evaluation
Up and Running: Analysis
Up and Running: Reports

 

powered by Typeform
Log in

Register